Mecosa logo



We Measure Level of Liquids and Solids
For a detailed product description please contact MECOSA or the Manufacturer's Web site

product Category product picture Brief product description manuf. web site

Mechanical Liquid Level Switches

NGS
Density range: ≥0,7 kg/dm3
Material: SS, Aluminium bronze,
sea water resistant
Max. temperature: 250 °C
Max. pressure: 2 500 kPa
Connection: flange, BSP, NPT
kobold.com

Tuning Fork Liquid Level Switches
for Viscous Materials

NWS
Max. viscosity: 5 000 mm2/s
Output: Electronic switch
Material: SS
Max. temperature: 130 °C
Max. pressure: 4 500 kPa
Connection: flange, BSP, NPT, TriClamp, hygienic
Ex-proof: ATEX
kobold.com

Nuclear
Level Switches

nuclear level switch
Detectors:
GM, Scintillation Counter, Super-Sens
Housing material: SS
Max. temperature: 60 °C, opt. water cooling
Evaluation Unit:
19" rack mounting, opt. wall mounting
Required power 18 - 30 V DC, opt. 110/230 V
Output: 3 relay (alarm, failure, warning)
Display: 2 lines LCD
Set-up: fully programmable
ATEX
bertholdtech.com

By-pass
Level Gauges

MBSK
Max. measuring length: 6 m, >6 m = 2-parts
Max. viscosity: 200 mm2/s
Min density: 0,4 kg/dm3
Accuracy: ± 5 mm of range
Material: SS
Max. temperature: 400 °C
Max. pressure: 32 000 kPa
Connection: flanges DIN or ANSI
Optional: analogue output; alarm contacts
Ex-proof: ATEX
heinrichs-mt.com

Level or Interface Indicator for Liquids
acc. to Archimedes Principle

BA
Max. measuring length: 6 m
Density range: 400 - 2 000 g/l
Accuracy: ± 5 mm of range
Material: SS, Hastelloy C
Max. temperature: 250 °C
Max. pressure: 32 000 kPa
Connection: flanges DIN or ANSI
Optional: analogue output; alarm contacts
HART®, Profibus PA®, Fieldbus, ATEX
heinrichs-mt.com

Capacitive Level Sensors for Liquids

NMC
Max. measuring length: 4 m
Accuracy: ± 2 mm of range
Material: SS with PTFE or PVDF coating
Max. temperature: 125 °C
Max. pressure: 1 000 kPa
Connection: BSP, NPT
Required power: 12 ... 30 V DC
Ex-proof: ATEX
kobold.com

Nuclear Level Gauges
Rod Source

nuclear rod source
Point detector: Scintillation Counter NaI(Ti)
Crystal size: 25/25, 40/35 or 50/50
Automatic drift compensation
Housing material: SS
Max. temperature: 60 °C, opt. water cooling
Evaluation Unit:
19" rack mounting, opt. wall mounting
Required power 18 - 32 V DC, opt. 110/230 V
Signal output: analogue and digital
Display: 4 lines LCD
Set-up: fully programmable
Interface: RS 232 & RS 485
ATEX
bertholdtech.com

Nuclear Level Gauges
Rod Detector

nuclear point source
Rod detector: Plastic Scintillation Counter Detector length: 500 mm to 2 000 mm
Automatic drift compensation
Housing material: SS
Max. temperature: 55 °C, opt. water cooling
Evaluation Unit:
19" rack mounting, opt. wall mounting
Required power 18 - 32 V DC, opt. 110/230 V
Signal output: analogue and digital
Display: 4 lines LCD
Set-up: fully programmable
Interface: RS 232 & RS 485
ATEX
bertholdtech.com

"Uni-Probe"
Combined
Level Detector/
Transmitter

Uniprobe
This combined level detector/transmitter may be used as a point detector, serving as a level switch, or in conjunction with a rod source as a continuous level transmitter. The "Uni-Probe" may also be use as a rod detector (maximum length: 2 m) for continuous level measurement.
Point Detector: Scintillator 50/50 NaI Crystal
Sensitivity: 0,5 µSv/h for 300 cps
Rod Detector: Plastic scintillator
Detector length: 500 mm to 2 000 mm
Signal output: analogue and digital
Housing material: SS 316 Ti
Max. temperature: 50 °C, opt. water cooling
Required Power: 18-32 V DC or 95-250 V AC
HART®, ATEX, Profibus PA, Fieldbus.
bertholdtech.com

"Tower-Sens"
Combined
Modular
Long-Range
Level Detector/
Transmitter

tower sense
Each "Tower-Sens" system could consists of a basic module and several extension modules, depending on the measuring length. The basic module includes a plastic scintillator rod and the entire electronic of the measuring system plus the communication interface. The extension module consists of a plastic scintillator rod encapsulated in SS and is coupled optically & mechanically with the basic module or another extension module.
Basic module length: Either 1 or 2 m
Extension module length: 2 m
Maximum measuring length per system: 8 m
Sensitivity: 0,5 µSv/h for 300 cps
Signal output: analogue and digital
Housing material: SS 316 Ti
Max. temperature: 50 °C, opt. water cooling
Required Power: 18-32 V DC or 95-250 V AC
Interface: RS 232 & RS 485
HART®, Profibus PA®, Fieldbus, ATEX
bertholdtech.com

Nuclear Mould
Level Gauge

LB 452
Detectors: Scintillators Csl 40/50 or 25/50
Max. Sensitivity: 5,1 µSv/h for 300 cps
Max. temperature: 50 °C, opt. water cooling
Protected against electromagnetic fields
Housing material: SS316 Ti
Extremely fast: cycle time of 5 ms
Evaluation unit: 19" module
Up to 4 measuring channels
Signal output: analogue and digital
Required Power: 90 - 260 V AC
Software: Windows CE
Interface: RS 485, Profibus DP®,
bertholdtech.com

Eddy Current Mould Level Gauge

ECcast
Measuring principle: A coil within the sensor generates an electromagnetic field. As a result eddy currents are induced in the top layer of the molten steel. These eddy currents in turn generate a counteracting electromagnetic field at the sensor - its strength is directly proportional to the distance between the molten steel surface and the sensor coil.
Sensor dimensions: 63 x 150 x 540 mm
Max. temperature: 180 °C, opt. water cooling
Measuring range: 10 to 200 mm
Accuracy: ± 0,2 mm of nominal range
Response time: 50 ms or higher, adjustable
Evaluation unit: 19" module
Up to 4 measuring channels
Signal output: analogue and digital
Required Power: 90 - 260 V AC
Software: Windows CE
Interface: RS 485, Profibus DP®,
bertholdtech.com